| Item
# |
Watts |
Ballast
Type |
Correlated
Color Temperature (CCT) |
Color
Rendering Index (CRI) |
M.O.L (Inches) |
Diameter
(Inches) |
Initial
Lumen |
Power
Factor |
Total
Harmonic Distortion |
Lamp Shape |
| 88890 |
55 |
Electronic |
2700-6400°K |
84 |
8.5 |
4.8 |
4400 |
>0.90 |
>0.30% |
Flower |
| 88891 |
75 |
Electronic |
2700-6400°K |
85 |
11 |
6 |
6000 |
>0.90 |
>0.30% |
Flower |
| 88892 |
95 |
Electronic |
2700-6400°K |
86 |
11 |
6 |
7500 |
>0.90 |
>0.30% |
Flower |
| 88893 |
105 |
Electronic |
2700-6400°K |
87 |
11.5 |
6 |
9500 |
>0.90 |
>0.30% |
Flower |
| |
|
Electronic |
2700-6400°K |
88 |
|
|
|
>0.90 |
>0.30% |
|
| 88898 |
150 |
Electronic |
2700-6400°K |
88 |
14 |
5 |
13875 |
>0.90 |
>0.30% |
U |
| 88993 |
200 |
Electronic |
2700-6400°K |
89 |
14 |
5 |
19000 |
>0.90 |
>0.30% |
U |
|
Savings
| *
Save Up to 75% on Electricity Costs for Lighting versus HID Lamps |
|
| *
Lamps Generate over 700% Less Heat than HID Bulbs & Reduces Air
Conditioning Costs |
| *
Long Lasting Fluorescent Lamps - Life Rated to 25,000 Hours |
|
| *
Electronic Ballasts Built into Lamps - No More Costly Ballast
Replacements |
| *
Electronic Ballasts Allow for Cold Weather Starts & No-Flicker |
| *
Screw In Bases Make for Easy Changing in Hard to Reach Locations -
Saves Labor Costs |
| *
Made in ISO-9002 Certified Factory |
| *
Energy Star Partner |
| *
Lamps UL and CSA Approved |
|
|
|
Operating
Temperature : |
| Long
Lasting Fluorescent Bulbs w/Electronic Ballasts |
Incandescent
Bulbs |
HID
- High Intensity Discharge Bulbs w/Magnetic Ballasts |
| 125W
- 90° F |
500W - 500° F |
400W Metal Halide - 842° F |
| 150W
- 90° F |
500W - 500° F |
400W Metal Halide - 842° F |
| 200W
- 90° F |
500W - 500° F |
400W Metal Halide - 842° F |
| 105W - 90° F |
500W - 500° F |
400W Metal Halide - 842° F |
| 95W - 90° F |
400W - 500° F |
250W Metal Halide - 850° F |
| 75W - 90° F |
300W - 500° F |
200W Metal Halide - 810° F |
| 55W - 90° F |
250W - 500° F |
175W Metal Halide - 800° F |
|
|
* LL Fluorescent vs. Incandescent 455% Less in Temperature
* LL Fluorescent vs. HID 788% Less in Temperature
* Save on air conditioning costs |
|
Operating cost: |
| Long
Lasting Fluorescent Bulbs |
Metal
Halide (HID) Bulb |
Cost
to Operate Metal Halide (HID) in KW Hrs @ .10 per KW Hr for 10,000 hrs |
Cost
to Operate LL Fluorescent Bulb in KW Hrs @ .10 per KW Hr for 10,000
hrs |
Savings
on Power Usage Between Bulbs @ .10 per KW for 10,000 hrs |
Percent
Difference |
| 88892 95W |
175 |
$262.00 |
$96.00 |
$166.00 |
173% |
| 88893
105W |
200 |
$300.00 |
$107.00 |
$193.00 |
180% |
| 88898
150W |
250 |
$375.00 |
$153.00 |
$222.00 |
145% |
| 88993
200W |
400 |
$500.00 |
$204.00 |
$296.00 |
145% |
| Long
Lasting Fluorescent Bulbs |
Incandescent Bulb |
Cost
to Operate Incandescent Bulb in KW Hrs @ .10¢ per KW Hr for 10,000
hrs |
Cost
to Operate LL Fluorescent Bulb in KW Hrs @ .10¢ per KW Hr for 10,000
hrs |
Savings
on Power Usage Between Bulbs @ .10¢ per KW for 10,000 hrs |
Percent
Difference |
| 89401
55W |
175 |
$175.00 |
$55.00 |
$120.00 |
218% |
| 89402
75W |
250 |
$250.00 |
$75.00 |
$175.00 |
233% |
| 89403
95W |
400 |
$400.00 |
$95.00 |
$305.00 |
321% |
| 89404
105W |
500 |
$500.00 |
$105.00 |
$395.00 |
376% |
|